Combi Units |
|
| COMBINATION UNITS - BS3198: 1981 |
| |
| |
 |
|
Albion combination
units offer traditional open vented stored hot water in
either direct, indirect or single feed patterns. The full
British Standard range is available, other sizes can be
made to requirement.
By storing the cold supply, tanks can be taken from the
loft space. Installation is made simpler without the need
to run pipes to and from the cold cistern. |
|
|
|
| COMBINATION
UNITS - TECHNICAL SPECIFICATIONS |
| With
an integrated cold supply, these units offer a practical and efficient
solution where space and easy installation are important factors.
|

BS3198:1981 |
|
|
 |
| |
|
 |
|
|
MATERIALS |
| |
|
Shell all copper to
BS 2870 with zinc free brazing alloy.
Tubes to BS EN 1057.
Aluminium close fitted lid. |
|
|
TAPPINGS |
| |
|
Three male or female
up to 1".
Immersion Heater Boss 2 1/4".
Drain Boss 1/2" female.
All sizes comply with BS 1566:2002 and are kitemarked
Special sizes to order. |
|
|
|
|
| AQUAPACK
UNITS |
|
|
Complete integrated units
constructed on a steel frame with all interconnecting pipework.
These are available as direct, indirect and Maxistore pattern units.
The cold tank is a black polythene cistern conforming to WRc requirements
and all ancillary fittings conform to relevant standards.
Cold tank capacities are available as follows -
please state when ordering.
INDIRECT
205 litres (45 gallons)
114 litres (25 gallons)
DIRECT
227 litres (50 gallons)
182 litres (40 gallons)
114 litres (25 gallons)
Indirect cisterns have an integrated feed and expansion tank for primary
circuits. |
|
|
| |
|
|
Heights are given for 50
gallon cold, direct cylinders. All other types are within these dimensions.
Aquapack units combine a cold feed tank with either a direct or indirect
Albion grade 3 copper cylinder.
A steel frame supports the tank.
The cold feed 227 litre polythene cistern must comply with model byelaw
30 when fitted.
All copper tube and fittings comply with the relevant British Standards. |
|
|
| |
 |