Superduty |
| |
| SUPERDUTY
High efficiency
coupled with space saving economy |
| |
| |
 |
Superduty
will also improve your combination boiler performance
- click here.
|
|
|
Ultra
fast recovery of hot water allows for a
reduction in cylinder size. This development has
resulted in the product we know today as the
Superduty, a cylinder used and specified by energy conscious
Local Authorities, Housing Associations and private builders
alike.
All Albion Superduty cylinders are WRc listed and NHBC approved.
FUEL
SAVING
The installation of a Superduty will reduce boiler
operating times and cycling periods resulting in
savings of up to 40% compared with systems using conventional
indirect cylinders.
IMPROVES
BOILER EFFICIENCY
The effective heat transfer of the Superduty results in
very cool primary return temperatures, which maintain the
boiler operation on full load - even in the summer months
!
This virtually eliminates expensive boiler cycling, a major
contribution to fuel saving. |
|
| |
SUPERDUTY |
| |
 |
|
| |
CF45 |
| |
Plenty of hot water
for a standard bath and gravity shower in any home. |
| |
| |
CF80 |
| |
Plenty of hot water
for a single bath and pumped shower. |
| |
| |
CF120 |
| |
Plenty of hot water
for larger baths or twin bathroom properties. |
|
Unlike
a conventional cylinder which utilises a single 28mm diameter
coil, Superduty multicoils are engineered with a manifold
which divides into four coiled tubes. This arrangement ensures
that far more water is in contact with the copper wall of
the heat exchanger, dramatically improving heat transfer between
primary and secondary waters.
The Superduty Multicoil heat exchanger is proven to provide
cost effective operation and performance, unparalleled in
systems of this type.
Just look at the performance graphs! |
|
|
|
|
| |
 |
|
| |
900 x 450 British
Standard |
| |
Plenty of hot water for a
standard bath
and gravity shower in any home. |
| |
| |
Superduty CF45 |
| |
Plenty of hot water for a
single bath
and pumped shower. |
| |
| |
Superduty CF80 |
| |
Plenty of hot water for larger
baths
or twin bathroom properties. |
|
|
PLENTY
OF HOT WATER |
|
| RECOVERY
TIMES (minutes) |
| BOILER
SIZE |
30Kw |
24Kw |
15Kw |
12Kw |
9Kw |
|
CF45 |
|
5 |
8 |
10 |
15 |
| |
|
9 |
15 |
18 |
24 |
| |
|
12 |
20 |
24 |
30 |
|
|
|
|
The above recovery times
are based on a primary flow of 82°C and a recovery from 20°C through
to 60°C. Times quoted are greater than the Albion bench test in order
to provide figures which are easily achievable in the home.
A practical example is to compare the hot water available from a CF45 against
that from a standard indirect 900 x 450mm cylinder. Using a 15Kw boiler
the standard cylinder will deliver approximately 175 litres of hot water
per hour (based on 40minutes recovery). The Superduty CF45 will produce
approximately 340 litres in these circumstances
(8 minutes recovery). |
|
| |
|
| |
|
SUPERDUTY |
|
| |
|
 |
Superduty Cisternflow cylinders
are suitable for fully pumped primary systems fuelled from mains
gas, lpg or oil boilers.
They are compatible with W, Y and S plan systems.
Quicker re-heat times are acheived with W plan systems.
A probe type insertion thermostat is required to provide increased
temperature sensing and accuracy over that of the strap-on type.
A connection is provided on each Superduty for this fitment. |
|
|
PRIMARY
CONNECTIONS
CF45 to CF140 22mm compression
All other sizes 1" male B.S.P. Albitec compliant
SECONDARY CONNECTION
CF45 to CF140 22mm compression
All other sizes 1" female B.S.P.
Secondary return: standard 22mm compression on all sizes
120 litre and above.
THERMOSTAT CONNECTION
1/2" female B.S.P. to all models.
IMMERSION HEATER CONNECTION
2 1/4" BSP female in all models.
MAXIMUM WORKING HEAD
10 metres, all models, (15 & 25 metre working head
available to order).
INSULATION
Albion Ecofoam CFC free.
COMBINATION UNITS
All Cisternflow models are available in combination
tank form supplied with byelaw 30 kits and lids.
CF45, CF80, and CF120 litre units have
20 litres of cold storage.
CF140, CF160, CF180 and CF210 litres units have
40 litres of cold storage.
GUARANTEE
Superduty cylinders are guaranteed for 5 years. |
|
SUPERDUTY
COMBINATION UNITS |
|
| |
|
| |
CF COMBI SIZES |
| CF45
COMBI |
950
x 350 mm |
| CF80
COMBI |
|
| |
|
| |
|
| |
|
| |
|
| |
|
|
|
|
|
|
| |
|
PRESSURE DROP ON SUPERDUTY COIL
|
|
| |
|
| Flowrate
through coil
|
PRESSURE
DROP
(kpa) |
L/S |
L/M |
| 0.05 |
3.0 |
1.0 |
0.10 |
6.0 |
3.3 |
0.15 |
9.0 |
6.4 |
0.20 |
12.0 |
10.5 |
0.25 |
15.0 |
14.2 |
0.30 |
18.0 |
20.9 |
0.35 |
21.0 |
28.2 |
0.40 |
24.0 |
37.0 |
0.45 |
27.0 |
47.3 |
0.50 |
30.0 |
58.0 |
0.55 |
33.0 |
70.5 |
|
|
|
|
| |
|
| THE
GREEN ISSUE |
|
| |
|
All Superduty
cylinders are insulated with a CFC free factory applied insulation unique
to Albion.
In addition there is a reduction in boiler emissions into the atmosphere
due to reduced boiler operating times and cycling periods. |
|
| |
|
| CONDENSING
BOILERS |
|
| |
|
| Cool return temperatures
and full load demand are particularly beneficial to condensing boilers,
keeping them in condensing mode during water heating cycles. |
|
| |
|
| SHOWERFLANGE |
|
| |
|
 |
|
Showerflange is particularly
suited to Superduty where the use of an immersion heater is not recommended.
The Flange converts a 2 1/4" Heater Boss into a 22mm compression fitting
for a bespoke shower connection. |
|
| |
| IMPROVE
YOUR HOT WATER FLOW USING ALBION SUPERDUTY
WITH YOUR EXISTING COMBI. |
|
 |
The energy efficient Superduty
CF45 measures
only 600mm x 350mm yet provides ample hot
water for a standard 1700mm bath.
Coupled with your existing combination boiler you can enjoy a bath
full of hot water in just a few minutes.
Bigger bath? No problem - Superduty is available in larger sizes.
In addition, all sizes are available with built in cold tanks if a
tank-free loft is required - ask for Superduty combination units. |
|
|
|
SUPERDUTY FOR OPEN VENTED HOT WATER |
| |
 |
 |
|
| |
|
 |